LUMERE LED Tester
The LUMERE LED tester is a fully-integrated test system that connects to a Windows XP Pro or Windows 2000 computer using a high-speed USB 2.0 connection. It can rapidly provide spectral and electric test information via a user-friendly graphical interface.
Features Of LUMERE LED tester:
- Extremely fast LED measurements with results in milliseconds
- User-friendly software that simplifies complex measurements
- High-speed USB interface with PC
- Provides up to 480Mbps communication bandwidth between test system and PC
- On-site NIST traceable recalibration capability
- Digital I/O standard supports
- 3.3-V Low Voltage Transistor-transistor Logic (LVTTL) and 3.3-V Low Voltage Complimentary Metal Oxide Semiconductor (LVCMOS) I/O standards support for digital channels
- Digital channels are 5.0-V TTL compatible
- Fast edge rates for digital signals
- Precision Measurement Unit (PMU) or Source & Measurement Unit (SMU)
- Up to +/-12V of voltage forcing range
- Voltage forcing and clamping capability
- Up to +/-800mA of current forcing range
- Current forcing and clamping setting capability
- Windows XP Pro and Windows 2000 compatible software
Execution Speed:
- Minimum source-delay-measure cycle time: 1ms
- Interface: USB 2.0 (high speed)
- Hardware Measurement rate: 0.005ms
- Software continuous reading rate: Operating system dependant
Forcing Current Compliance:
- Compliance: Bipolar voltage limit set with single value
- Maximum: +/-10V
- Minimum: +/- 1% of current range
- Accuracy, step size: 8-bit step
Forcing Voltage Compliance:
- Compliance: Bipolar current limit set with single value
- Maximum: +/-200mA
- Minimum: +/- 1% of current range
- Accuracy, step size: 8-bit step
Technocal Data For Optical Test:
The spectrometer is based on the symmetrical Czerny-Turner design with 2048 pixel CCD Detector Array optical bench. The spectrometer has a fiber optic entrance connector (standard SMA, other possible), collimating and focusing mirror and diffraction grating.
Spectrometer
- Detector: 2048 pixel CCD
- Pixel Width/Height: 14 x 56µm
- Grating: 600 lines/mm
- Blaze: 370nm
- Useable Range: 330nm - 850nm
- Pixel Dispersion: <0.3 nm
- Data Point: 0.25nm
- Focal Length: 75mm
- Slit: 25mm
- Sensitivity: 240 V/lx.s
- Sensitivity (using 8 µm in counts per ms integration time): 5000 counts/µW per ms integration time
- Resolution (FWHM): 0.7
- Signal/Noise: 250:1
- AD Converter: 14 bit, 2Mhz
- Integration time: 1.1 msec - 10 minutes
- Data Transfer Speed: 2.0 msec/scan
- Communication: USB 2.0 high speed, 480Mbps
- Input Optics: 600µm
- Fiber Connector: SMA
- Fiber Type: Multimode, Step Index Fiber
- Dimension: 175x110x44 mm
- Weight: 716 grams
Parameter:
The LUMERE (Led Tester) reports the radiometric, photometric and colorimetric parameters. The parameters are stated as below:
- Radiant Flux (µWatt)
- Luminous Flux (lm)
- Radiant Intensity (µWatt/sr)
- Luminous Intensity (Cd)
- Irradiance (µWatt/cm2)
- Illuminance (Lux = lm/cm2)
- Peak Wavelength (nm)
- Bandwidth (FWHM) (nm)
- Dominant Wavelength (nm)
- Central Wavelength (nm)
- Centroid (nm)
- CIE X,Y, u, v color coordinates
- CCT (oC)
- Purity
- Energy emitted (µJoule)
- Radiant Energy (µJoule/sr)
- Energy/cm2 (µJoule/cm2)
- Photon Flux/m2 (µMol/(s.m2))
- Photon Flux (µMol/s)
- Photon/m2 (µMol/m2)
- Photons (µMol)
File under Automated Testing Solution | September 2nd, 2006